High-efficiency protection without compromise
	Three/single and three/three phase from 10 to 40 kVA/kW

The solution for
- Data centres
 - Telecommunications
 - Healthcare sector
 - Service sector
 - Infrastructure
 - Industrial applications
 
Advantages
Energy saving + Full rated power = TCO
Energy Saving: high efficiency without compromise
- Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that assures total load protection against all mains quality problems
 - Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating conditions, to have the value in the real site conditions
 - Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power 2.0 UPS ranges
 
Full-rated power: kW=kVA
- No power downgrading when supplying the latest generation of servers (leading or unity power factor)
 - Real full power, according to IEC 62040: kW=kVA (unity power factor design) means 25% more active power available compared to legacy UPS
 - Suitable also for leading power factor loads down to 0.9 without apparent power derating
 
Significant cost savings (TCO)
- Maximum energy saving thanks to 96% output efficiency: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill
 - UPS “self-paying” with energy saving
 - Energy Saver mode for global efficiency improvement on parallel systems
kW=kVA means maximum power available with the same size of UPS, and therefore less €/kW - Upstream infrastructure cost optimization (sources and distribution), thanks to high performance IGBT rectifier
 - Battery configuration can be optimized, thanks to a very wide DC range
 - Extended battery life and performance:
- long life battery,
- very wide input voltage and frequency acceptance, without battery use.
- EBS (Expert Battery System) charging management improves battery service life." 
Standard electrical features
- Dual input mains
 - Internal maintanance bypass
 - Backfeed protection: detection circuit
 - EBS (Expert Battery System) for battery management
 - External temperature sensor
 
Electrical options
- External maintanance bypass
 - External battery cabinet
 - Additional battery chargers
 - Galvanic isolation transformer
 - Parallel kit
 - ACS synchronization system.
 
Standard communication features
- User-friendly multilingual interface with color graphic display
 - Commissioning wizard
 - 2 slots for communication options
 - MODBUS TCP
 - MODBUS RTU
 - Embedded LAN interface (web pages, email)
 
Communication options
- Dry-contact interface
 - PROFIBUS
 - BACnet/IP interface
 - NET VISION: professional WEB/SNM interface for UPS monitoring and shutdown management of several operating systems
 
Remote maintenance
- LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24/7
 
Technical data
| Sn [kVA] | 
				
  | 
		|||||
| Pn [kW] | 
				
  | 
		|||||
| Input / Output 3/1 | 
				
  | 
		|||||
| Input / Output 3/3 | 
				
  | 
		|||||
| Parallel configuration | up to 6 units | 
INPUT
| Rated voltage | 400 V 3ph + N | 
| Voltage tolerances | 240 V to 480 V(1) | 
| Rated frequency | 50/60 Hz ± 10% | 
| Power factor / THDI | >0.99 / <2.5% | 
Output
| Power factor | 1 (according to IEC/EN 62040-3) | 
| Rated voltage | 3ph + N: 400 V (can be configured 380/415 V) | 
| Voltage tolerance | static load ±1% dynamic load in accordance with VFI-SS-111 | 
| Rated frequency | 50/60 Hz | 
| Frequency tolerance | ± 2% (configurable for GenSet compatibility) | 
| Total output voltage distortion - linear load | <1% | 
| Total output voltage distortion - non-linear load | <3% | 
| Overload | 125% for 10 minutes, 150% for 1 minute(1) | 
| Crest factor | 3:1 | 
Bypass
| Rated voltage | rated output voltage | 
| Voltage tolerance | ± 15% (configurable with from 10% to 20%) | 
| Rated frequency | 50/60 Hz | 
| Frequency tolerance | ± 2% | 
Efficiency (TÜV SÜD verified)
| Online mode @ 50 % of load | up to 96% | 
| Online mode @ 75 % of load | up to 96% | 
| Online mode @ 100 % of load | up to 96% | 
| Eco Mode | up to 98% | 
Environment
| Operating environment temperature | from 0 °C up to 40(1)°C (from 15 °C to 25 °C for maximum battery life)  | 
		||
| Relative humidity | 0% - 95% without condensation | ||
| Maximum altitude | 1000m without derating (max. 3000 m) | ||
| Acoustic level at 1 m (ISO 3746) | 
				
  | 
		
UPS cabinet
| Dimensions W x D x H | 
				
  | 
		||||
| Weight | 
				
  | 
		||||
| Degree of protection | IP20 | ||||
| Colours | RAL 7012 | 
Standards
| Safety | IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2 | 
| Electromagnetic compatibility (EMC) | IEC/EN 62040-2, AS 62040.2 | 
| Performance | IEC/EN 62040-3, AS 62040.3 | 
| Seismic compliance | On demand according to Uniform Building Code UBC-1997 Zone 4 | 
| Product declaration | CE, RCM (E2376) | 