Resilient transformer-based power protection
Three/three phase UPS from 80 to 200 kVA
The solution for
- Industry
 - Processes
 - Infrastructure
 - Healthcare
 - Service sector
 - Telecommunications
 
Advantages
High quality power supply
- Permanent operation in VFI mode (online double conversion)
 - Output voltage precision under all load conditions
 - High overload capacity to withstand abnormal load conditions
 - A very high short-circuit current capacity which facilitates the selection of protective devices for selectivity in the downstream distribution.
 - An isolation transformer installed on the inverter output to ensure complete galvanic isolation between DC circuit and load output. This insulation also provides a separation between the two inputs when they are supplied by different sources.
 - Sinusoidal ThdU output voltage < 2 % with linear loads and < 4 % with non-linear loads.
 
High availability
- Field-proven technology
 - Fault-tolerant architecture with redundancy of basic functions, such as the ventilation system.
 - Easy maintainability reduces MTTR thanks to pull-out sub-assemblies and front access all components.
 - Accurate diagnostics guarantee power supply to the load
 - Cascade failure prevention for parallel systems
 - Mechanical & electrical robustness for industrial environments
 - Soft start capability (ramp up) of the IGBT inverter allows a good operation even with a genset.
 - Specifically designed to be adapted to different industrial environment: high IP protection options, high peak current capability, long back up time
 
Cost-effective equipment
- The "clean" IGBT rectifier allows:
- a high efficiency,
- a high and constant input power factor,
- a low THDi. - These characteristics help to limit the dimensions of upstream network infrastructure.
 - Possibility to create new neutral system without additional losses (extra transformer required on by-pass line only).
 - High short-circuit capability simplifies downstream protective devices.
 - High power density: its small footprint saves space on your premises.
 - Mains connection of the rectifier requires only 3 cables (no neutral).
 - Battery connection to UPS requires only 2 cables
 
User-friendly operation
- A control panel with graphic display for more ergonomic operation.
 - An array of "com-slot" plug-in communication interfaces, for upgrading your operating requirements evolution.
 
Simplified maintenance
- An advanced diagnostic system
 - A remote access device connected to the remote maintenance centre.
 - Easy access to subassemblies and components, facilitating tests and reducing maintenance time (MTTR).
 
Parallel systems
- Distributed or centralized bypass for parallel architecture up to 6 units.
 - Redundant systems ("1+1" and "n+1").
 - "2n" architecture with Static Transfer Systems.
 
Standard electrical features
- Slots for 3 communication cards.
 - Backfeed protection: detection circuit.
 - Standard interface:
- 3 inputs (emergency stop, generating set, battery protection),
- 4 outputs (general alarm, back-up, bypass, preventative maintenance needs). 
Electrical options
- EBS (Expert Battery System)(2).
 - ACS synchronisation system for 2n architecture.
 - Redundant electronic power supplies.
 - Hot plug option (increase the power keeping the load supplied in double conversion).
 - Long back up time rectifier.
 
Mechanical options
- Reinforced IP protection degree.
 - Dust filters.
 - Fan redundancy with failure detection.
 - Top entry connection.
 - Reinforced IP protection up to IP52.
 
Communication options
- GTS (Graphic Touch Screen).
 - ADC interface (configurable voltage-free contacts).
 - MODBUS RTU.
 - MODBUS TCP.
 - PROFIBUS / PROFINET.
 - BACnet/IP interface.
 - NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.
 - 3 extra slots for communication cards.
 
Remote monitoring service
- LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24/7
 
Technical data
| Sn [kVA] | 
  | |||||
| Pn [kW] | 
  | |||||
| Input / Output | 3/3 | |||||
| Parallel configuration | up to 6 units (distributed or centralised bypass) | 
Input
| Rated voltage | 380 V - 400 V - 415 V(1) | 
| Voltage tolerances | 342 V to 460 V(2) | 
| Rated frequency | 50/60 Hz | 
| Frequency tolerance | 45/65 Hz | 
| Power factor / THDI | 0.99 constant / 2.5 % without filter | 
Output
| Rated voltage | 380 V - 400 V - 415 V (configurable)(1) | 
| Voltage tolerance | < 1 % (static load), ± 2 % in 5 ms (dynamic load conditions from 0 to 100 %) | 
| Rated frequency | 50/60 Hz | 
| Frequency tolerance | ± 0.2% | 
| Total output voltage distortion - linear load | ThdU <2% | 
| Total output voltage distortion - non-linear load | ThdU <4% | 
| Short-circuit current on inverter (100ms) | Up to 3.5 In | 
| Overload | 150% for 1 minutes, 125% for 10 minutes(2) | 
| Crest factor | 3:1 | 
Bypass
| Rated voltage | 380 V - 400 V - 415 V | 
| Voltage tolerance | ± 10% (selectable) | 
| Rated frequency | 50/60 Hz | 
| Frequency tolerance | ± 2% (configurable for GenSet compatibility) | 
| Short-circuit current on by-pass (20ms) | Up to 24 In | 
Efficiency
| Online mode | 93.5% | 
| Eco Mode | 98% | 
Environment
| Operating ambient temperature | from 0 °C up to 40(2)°C (from 15 °C to 25 °C for maximum battery life)  | ||
| Relative humidity | 0% - 95% without condensation | ||
| Maximum altitude | 1000m without derating (max. 3000 m) | ||
| Acoustic level at 1 m (ISO 3746) | 
  | 
UPS cabinet
| Dimensions W x D x H | 1000 x 800 x 1930 mm | |||
| Weight | 
  | |||
| Degree of protection | IP20 (other IP as option) | |||
| Colours | RAL 9006 | 
Standards
| Safety | IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2 | 
| EMC | IEC/EN 62040-2, AS 62040.2 | 
| Product declaration | CE, RCM (E2376) | 
(1) Others on demand.
(2) Conditions apply.